Comprehensive Control of the Noise Occupational Hazard

Comprehensive Control of the Noise Occupational Hazard

Jan 01, 2012 When noise level is up to 100 ~ 105dB, the detection rate of deaf induced by occupational noise is up to 52%, and hearing damage detection rate of high-frequency noise is nearly 60%. Long-term working in high-noise environments of the cement plant, influence of noise on neurasthenia syndrome is obvious, which causes insomnia, dizziness

Get Price
eTool : Woodworking - Production - Noise | Occupational

eTool : Woodworking - Production - Noise | Occupational

Noise levels can be reduced through the use of some or all of the simple and practical methods discussed below.These methods focus on three basic approaches to controlling noise: noise source controls, noise path controls, and hearing protection.Noise source controls, which typically consist of engineering controls, provide the most effective means of protection, since they actually reduce the

Get Price
LUMBER MILL NOISE AND ITS CONTROL William A. Dost

LUMBER MILL NOISE AND ITS CONTROL William A. Dost

by 1959. This focus on saw and planerhead noise served a very use-ful purpose but one result has been that industry personnel tend to under-rate other noise sources. Woodworking plant noise is the result of many pieces of equipment. The underlying reasons for the high noise levels in sawmills and planermills are easily recognized

Get Price
Boral Cement Limited

Boral Cement Limited

a A Noise Management Plan to outline measures to minimise the impacts from the operation of the cement works upgrade on local noise levels. Appendix 6 i. all major noise sources including those arising from the upgrade of Kiln 6 and the installation of Cement Mill 7 Section 6.1 ii. noise criteria for particular activities Table 3 iii

Get Price
5 NOISE SOURCES - WHO

5 NOISE SOURCES - WHO

5.2. INDUSTRIAL NOISE SOURCES In this section, the fundamental mechanisms of noise sources are discussed, as well as some examples of the most common machines used in the work environment. The sound pressure level generated depends on the type of the noise source, distance from the source to the receiver and the nature of the working environment

Get Price
10 ENGINEERING NOISE CONTROL - WHO

10 ENGINEERING NOISE CONTROL - WHO

Engineering noise control 249 Figure 10.2. Sound sources should not be placed near corners (ASF, 1977) include rejection of the proposed design. The first step for new installations is to determine the noise criteria for sensitive locations

Get Price
Ambuja Cement Plant

Ambuja Cement Plant

cement mill and bag filter at all the transfer points shall be installed. Coal and clinker storage will be in the form of stockpile. The dust collected from the ... various noise generating sources. The ambient noise level monitoring report is enclosed as Annexure II

Get Price
eNoise Control | Sound Blankets & Curtains | Acoustic

eNoise Control | Sound Blankets & Curtains | Acoustic

Let us help you with construction site sound blankets, sound walls, acoustic consultation, sound surveys and evaluation work. eNoise has industrial engineered acoustic solutions and off-the-shelf options for quick-ship needs. Call or email us today! [email protected] Call Today at. 317.774.1900

Get Price
NCC CEMENT PLANT AND QUARRY EXPANSION

NCC CEMENT PLANT AND QUARRY EXPANSION

NORTHERN CEMENT CORPORATION EPRMP SUMMARY FOR THE PUBLIC (ESP) NCC CEMENT PLANT AND QUARRY EXPANSION PROJECT Brgy. Labayug, Sison, Pangasinan 3 2.0 PROPOSED LOATION The proposed expansion of the cement plant facility will be within the existing 43.06-hectare NCC plant complex in Brgy.Labayug, Sison, Pangasinan

Get Price
ENVIRONMENTAL IMPACT STATEMENT SUMMARY

ENVIRONMENTAL IMPACT STATEMENT SUMMARY

Cement Grinder 2 unit Vertical Roller Mill with 260tph and 300tph capacity 2 unit Vertical Roller Mill with 260tph and 300tph capacity Cement Silo 4 units x 10,000 MT capacity 4 units x 10,000 MT capacity Water Source deep well deep well Air Pollution Control Bag house filters Dust collectors Bag house filters Dust collectors Wastewater

Get Price
Environmental Guidelines for Cement Manufacturing

Environmental Guidelines for Cement Manufacturing

335 Cement Manufacturing Air Emissions Ambient Noise A maximum emissions level of 50 milligrams per normal cubic meter (mg/Nm3) (equivalent to a maximum of 0.2 kg/t of clinker) for particulates in stack gases under full load conditions is to be achieved. This emission level is based on values that are routinely achieved in well-run plants

Get Price
Air Pollution Control in the Cement Industry

Air Pollution Control in the Cement Industry

portioned and conveyed to the raw mill grinding system which generally consists of a mill in closed circuit with an air separator for product classification. Partial drying may be accomplished in the mill circuit by supplemental heat. Materials in transit through the system are conveyed typically by means of screw conveyors, elevators and air slide

Get Price
Ecology & Safety Journal of International Scientific

Ecology & Safety Journal of International Scientific

Ecology & Safety ISSN 1314-7234, Volume 9, 2015 Journal of International Scientific Publications www.scientific-publications.net Table 1. Raw materials necessary for cement manufacturing (God n.d.)

Get Price
Noise Source Decibel - Purdue University

Noise Source Decibel - Purdue University

Noise Source Decibel Level comment; Jet take-off (at 25 meters) 150: Eardrum rupture: Aircraft carrier deck: 140 : Military jet aircraft take-off from aircraft carrier with afterburner at 50 ft (130 dB). 130 : Thunderclap, chain saw. Oxygen torch (121 dB). 120: Painful. 32 times as loud as 70 dB. Steel mill

Get Price
Mill Noise Level Report - Ref A FvdM

Mill Noise Level Report - Ref A FvdM

Various sources reported on measured noise levels of conventional ball mills (as very potent generator of cement plant noise). Other sources were consulted for noise levels of vertical (roller) mills where it was found that the noise was mainly originating from the motor and gearbox. The table that follows give a good indication of noises that can be expected at around 4.572 meter

Get Price
eTool : Woodworking - Rough Mill - Noise | Occupational

eTool : Woodworking - Rough Mill - Noise | Occupational

Source control begins with a thorough analysis of each piece of noise-generating equipment. Attempt to identify all noise sources within a given piece of equipment, as well as the ways in which the sound is transmitted (and often amplified via resonance or vibration) to the surrounding room

Get Price
How to Read a Portland Cement Mill Test Report

How to Read a Portland Cement Mill Test Report

Skyway Cement Company, LLC How to Read a Portland Cement Mill Test Report . ASTM C150 – Portland Cement Specification • Due to overlaps in requirements and strength levels typically well above ... Uniformity From a Single Source Mill Test Reports. ASTM C150 – Portland Cement

Get Price
CEMENT INDUSTRY POLLUTION CONTROL MEASURES

CEMENT INDUSTRY POLLUTION CONTROL MEASURES

Following methods may be employed to control noise pollution in cement industry. 1. Using vibration damping pads, isolating vibrating parts etc. to reduce noise pollution in cement industry. 2. By enclosing the source and making them sound insulated. 3. Using personal noise

Get Price
Cement milling Question 1 - Page 1 of 26

Cement milling Question 1 - Page 1 of 26

Cement milling Question 1. Recently, we have changed the grinding balls in the second chamber of our mill to a lower size balls. The effect is a 10 per cent of reducing in fineness at the discharge of the mill, therefore the efficiency of our separator is better, but we were waiting for an increase in the production, nevertheless it is the same than past periods with bigger balls

Get Price
Acoustic Analysis of Machineries in the Cement Industry

Acoustic Analysis of Machineries in the Cement Industry

By using the data in Table 1, the most infamous noise emission sources in this factory are summarized in Ta-ble 2. According to Table 1 and Table 2, it can be concluded that the noisiest source is the crusher unit with the mean SPL 102.4 dB at its basement. Among the nine units, the packing unit, kiln to cement mill and crusher to

Get Price
Boral Cement Limited Berrima Works

Boral Cement Limited Berrima Works

monitoring equipment. Noise meter is required to be calibrated as specified by the manufacturers’ instructions. 5.3 NOISE PRP The current site limits for the noise relate only to Kiln 6 and Cement Mill 7 operations. The site as a whole does not have a noise limit. This gap in the regulatory approach has recently been recognised by the Authorities

Get Price
Related News